AVAILABLE NOWR Schmitt Enertec ENERGY-LINE M12 G500 50 Hz Natural Gas Generator Set
- Germany
- New
- Electrical ratings: 500 / 450 / 400 kW ESP / PRP / COP
Review the main specifications, condition, location, availability and supporting details for this offer.
The turbine is a 17-stage compressor machine running at 5,132 rpm with diesel-engine starting. The BHEL generator is rated 36,463 kW at 50°C, 50 Hz and 3,000 rpm. The BHEL generator transformer is rated 35,419 kVA at 50°C and 0.8 power factor. Recorded operating history is 180,944.91 fired hours and 388 starts. Last Major Inspection was completed in February 2025, Hot Gas Path inspection in March 2021 and combustion inspection in March 2024.
Application: Captive power generation; dual-fuel gas turbine package primarily operated on natural gas
| Turbine manufacturer | General Electric supplied by BHEL |
|---|---|
| Turbine model | Frame 6B (6551) |
| Commissioning | June 1998 |
| Fuel | Dual fuel primarily natural gas |
| Design capacity | 29,130 kW at base load on gas |
| Turbine speed | 5,132 rpm |
| Starting method | Diesel engine |
| Compressor | 17 stages |
| Generator manufacturer | BHEL, India |
| Generator capacity | 36,463 kW at 50°C |
| Generator frequency | 50 Hz |
| Generator speed | 3,000 rpm |
| Transformer capacity | 35,419 kVA at 50°C, PF 0.8 |
| Transformer manufacturer | BHEL, India |
Technical preview · copying/printing is discouraged. Screenshot prevention cannot be guaranteed on the open web.
Gas turbine package; gas fuel skid system; diesel supply system for starting diesel engine; enclosures from starting diesel engine to exciter; generator exciter; load gearbox and auxiliary gearbox; turbine control panel/control system; lube oil system and fuel skid; inlet air filtration and exhaust stack; control-room battery charger; auxiliary transformer/UAT; AVR; Mark VIe operating and control panel; generator control panel; MCC cabinet; stack; inlet air filter unit; water pumps and accessories for fire-fighting system; compressor; DG set; lube oil cooling system; 11 kV and 33 kV cabling up to switchgear room; turbine monitoring system; auxiliary diesel tank; turbine offline washing skid; tools and tackles available for MI/HGPI.
Tender No. 07/2026 including detailed scope of work, maintenance record, inclusions/exclusions, tender conditions and vendor-registration requirements